5
CS Soft Professional with leakage calculation
The data collected in DS 300 can be evalu-
ated by means of the newly developed
CS Soft Professional with leakage calcula-
tion which was especially developed for the
compressed air branch.
1. How is leakage determined?
The easiest way is the leakage deter-
mination on production-free days,
e. g. weekends, holidays, at the end of
a shift. During this time the compressor
carries compressed air which is re-
quired to keep a constant pressure.
According to statistics even if produc-
tion is effected day and night there is
at least one short period of time during
which all load is switched off, e. g.
maintenance times.
This period of time is determined auto-
matically by the CS Soft Professional.
2. What has to be done by the user?
The user has to enter the following
parameters:
- Current costs per kWh
- Meas. rate, duration of measurement
3. Which evaluations does the user get?
Apart from the graphic evaluation with
curve progressions of all measured
data the customer will get information on:
- the total air consumption in m³
- the leakage in total in m³ and % of the
total air consumption
- the current consumption in kWh
- costs per m³ of produced compressed
air in
- costs of the leakage in
- pressure progression
- pressure dew point progression
Please take order details and further accessories
from the price list
COMPLETE FLOW STATION
WITH MEASURING SECTION: ORDER NO.
DN 6 up to 85 l/min 0601 0160
DN 15 up to 750 l/min 0601 0161
DN 20 up to 85 m
³
/h 0601 0162
DN 25 up to 140 m
³
/h 0601 0163
DN 32 up to 260 m
³
/h 0601 0164
DN 40 up to 360 m
³
/h 0601 0165
DN 50 up to 600 m
³
/h 0601 0166
DN 65 up to 1,100 m
³
/h 0601 0167
DN 80 up to 1,600 m
³
/h 0601 0168
DN 100 up to 2,700 m
³
/h 0601 0169
DN 125 up to 4,000 m
³
/h 0601 0170
DN 150 up to 5,800 m
³
/h 0601 0171
DN 200 up to 8,800 m
³
/h 0601 0172
ACCESSORIES ORDER NO.
Option DS 300 with RS 485 and 0500 3220
data logger for 500,000 measuring
values, incl. 2 additional plug-in cards
CS data collector for reading out and 0554 7000
programming up to 64 x DS 300
Basic software for easy 0599 2000
configuration of DS 300
CS Soft Professional, data evaluation 0554 7010
in graphic and table form with USB cable
CS Soft Professional RS 485, data 0554 7020
evaluation in graphic and table form
with cable RS 485/USB
CS compressed air analysis software 0599 2010
for leakage and cost calculation
Clamp-on ammeter 0 to 500A 0554 0500
FA 300-21, pressure dew point probe 0699 3024
from -80 to +20 °Ctd
Pressure probe from 0 to 16 bar 0694 1886
5 point precision calibration with 3200 0001
ISO certificate
Compressed air analysis with leakage calculation
Meas. period 31.12.2006 until 31.01.2007, meas. rate 1 second
COMPRESSED AIR CONSUMPTION
Total consumption: Average consumption: Maximum consumption:
1,309,013 m³ 1,805 m³/h 2,400 m³/h
LEAKAGE
Leakage in total: Average leakage: Leakage rate:
299,000 m³ 415 m³/h 23 %
ENERGY DATA
Total energy consumption: Energy costs: Energy costs per m³:
129,000 KWh 129,000 KWh x 0.11 = 14,190 14,190 / 1,309,013 m³
= 0.011 /m³
FURTHER MEASURING DATA
Maximum pressure: Minimum pressure: Average value:
7 bar 5.8 bar 6 bar
Maximum dew point: Minimum dew point:
-11°Ctd -50 °Ctd
Leakage costs: 299,000 m³ x 0.011 = 3,289 for 1 month
DESCRIPTION:
Completely wired plug-in flow station consisting of:
DS 300 (with data logger for 500,000 measured values), current air consumption in m³/h, total consump-
tion in m³
including 2 additional plug-in cards (4 - 20mA, 0-10V, Pt100, TC) Consumption probe VA 300-80 standard
version, meas. sections from DN 6 to DN 200